[Full-Version] 2021 New Test4Cram 3V0-22.21 PDF Recently Updated Questions [Q10-Q25]

Share

[Full-Version] 2021 New Test4Cram 3V0-22.21 PDF Recently Updated Questions

3V0-22.21 Exam with Guarantee Updated 17 Questions


VMware 3V0-22.21 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Troubleshoot virtual machine reservations and VMware Admission Control
  • Set up VMware vCenter Server® and single sign-on (SSO)
Topic 2
  • Configure and manage advanced cluster configurations (Quickstart, Admission Control)
  • Configure the VMware Tools and vSphere® Client repository (productLocker)
Topic 3
  • Identify and implement vSphere® resource optimization opportunities
  • Performance-tuning, Optimization, and Upgrades
Topic 4
  • Create and manage host profiles (e.g. edit and apply host profiles)
  • Implement VMware vSphere® virtual machine encryption (VM encryption)
Topic 5
  • Configure and manage VMware vCenter Server® backup and restore options
  • Set up log collection and VMware vCenter Server® backup
Topic 6
  • Configure CPU scheduler for security options
  • Set up a cluster solution for VMware vSAN™

 

NEW QUESTION 10
Your security team is getting ready for an audit and wants to check the status of all ESXI hosts' outstanding security patches. Create a new fixed Update Manager baseline for all security ESXi host patches and name it ''Security patches. ''Use the patches available in the patch repository. Use VCSA01a in this task.
Baseline Name: Security Patches
Baseline Type: Host Patch
Category: Security

Answer:

Explanation:
The Update Manager displays system managed baselines that are generated by vSAN. These baselines appear by default when you use vSAN clusters with ESXi hosts of version 6.0 Update 2 and later in your vSphere inventory. If your vSphere environment does not contain any vSAN clusters, no system managed baselines are created.
The system managed baselines automatically update their content periodically, which requires Update Manager to have constant access to the Internet. The vSAN system baselines are typically refreshed every 24 hours.
You use system managed baselines to upgrade your vSAN clusters to recommended critical patches, drivers, updates or the latest supported ESXi host version for vSAN.
System managed baselines cannot be edited or deleted. You do not attach system managed baselines to inventory objects in your vSphere environment. You can create a baseline group of multiple system managed baselines, but you cannot add any other type of basline to that group. Similarly, you cannot add a system managed baseline to a baseline group that contains upgrade, patch, and extension baselines.

 

NEW QUESTION 11
The IT Team recently implemented a Unified Communication Service to provide conferencing for the organization. The UCS Application server is running from a virtual machine named VM1-UCS. Due to the nature of the UCS. the traffic for VM1-UCS has a higher Class of Service (CoS) demand.
In order to meet demand bandwidth for VM1 hosting the UCS. you been have given the task to improve performance by isolating the traffic and configuring CoS for this VM.
Your first task is to connect VM1-UCS to the distributed port group. UCS-Portgroup.
Your second task is to tag and mark the traffic for VM1-UCS with the following parameters:
* Name: UCS Network Traffic
* CoS Value: 4
* DSCP Value: 34
* Traffic Direction: Ingress/Egress
* Traffic Qualifier: System Traffic - Virtual Machine
The IT Team noticed that some of the parameter where not available on the distributed switch. Troubleshoot why these settings are missing and fix it.

  • A. Send us your suggestions.

Answer: A

 

NEW QUESTION 12
The company's IT strategy is to adopt innovative and emerging technologies such as software-defined storage solution. The IT team has decided to run their business-critical workloads on an all-flash Virtual SAN (vSAN) as it provides excellent performance.
The IT team has purchased servers that are compatible with vSAN. However, all the solid-state drives (SSD) in the servers are shown incorrectly as hard-disk drives (HDD) instead.
In addition, some of the solid-state drives (SSD) will be used for other purposes instead of vSAN and should not be part of the vSAN cluster. These are the requirements for the vSAN cluster:
* In each server, use the 3GB SSD as the cache tier and the 11GB SSD as the capacity tier
* As a result the vSAN cluster will use a total of six SSDs (three SSDs for caching and three SSDs for capacity
* Ensure all the disks that will be used for vSAN are shown correctly as SSDs
* Provide storage savings by using deduplication and compression.
Next, the IT team wants to improve the performance and availability of the business-critical workloads on the vSAN-datastore.
Ensure the following configurations will be applied on existing and new workloads located on vSAN-datastore:
Number of disk stripes per object: 2
Primary level of failures to tolerate: 2
Failure tolerance method: RAID-1 (Mirroring)
Force provisioning; Yes
The new configurations should be applied by default.
You may create new storage policy but do not edit the default vSAN storage policy as it may be used by other vSAN clusters in the future. Name the policy "New vSAN Default'.
Note: All tasks should be executed in PROD-A host cluster.

Answer:

Explanation:
VMware vSphere ESXi can use locally attached SSDs (Solid State Disk) and flash devices in multiple ways. Since SSDs offer much higher throughput and much lower latency than traditional magnetic hard disks the benefits are clear. While offering lower throughput and higher latency, flash devices such as USB or SATADOM can also be appropriate for some use cases. The potential drawback to using SSDs and flash device storage is that the endurance can be significantly less than traditional magnetic disks and it can vary based on the workload type as well as factors such as the drive capacity, underlying flash technology, etc.
This KB outlines the minimum SSD and flash device recommendations based on different technologies and use case scenarios.
SSD and Flash Device Use Cases
A non-exhaustive survey of various usage models in vSphere environment are listed below.
Host swap cache
This usage model has been supported since vSphere 5.1 for SATA and SCSI connected SSDs. USB and low end SATA or SCSI flash devices are not supported.
The workload is heavily influenced by the degree of host memory over commitment.
Regular datastore
A (local) SSD is used instead of a hard disk drive.
This usage model has been supported since vSphere 7.0 for SATA and SCSI connected SSDs.
There is currently no support for USB connected SSDs or for low end flash devices regardless of connection type.
vSphere Flash Read Cache (aka Virtual Flash)
This usage model has been supported since vSphere 5.5 for SATA and SCSI connected SSDs.
There is no support for USB connected SSDs or for low end flash devices.
vSAN
This usage model has been supported since vSphere 5.5 for SATA and SCSI SSDs. For more information, see the vSAN Hardware Quick Reference Guide.
vSphere ESXi Boot Disk
A USB flash drive or SATADOM or local SSD can be chosen as the install image for ESXi, the vSphere hypervisor, which then boots from the flash device.
This usage model has been supported since vSphere 3.5 for USB flash devices and vSphere 4.0 for SCSI/SATA connected devices.
Installation to SATA and SCSI connected SSD, SATADOM and flash devices creates a full install image which includes a logging partition (see below) whereas installation to a USB device creates a boot disk image without a logging partition.
vSphere ESXi Coredump device
The default size for the coredump partition is 2.5 GiB which is about 2.7 GB and the installer creates a coredump partition on the boot device device for vSphere 5.5 and above. After installation the partition can be resized if necessary using partedUtil. For more information, see the vSphere documentation.
Any SATADOM or SATA/SCSI SSD may be configured with a coredump partition.
This usage model has been supported from vSphere 3.5 for boot USB flash devices and since vSphere 4.0 for any SATA or SCSI connected SSD that is local.
This usage model also applies to Autodeploy hosts which have no boot disk.
vSphere ESXi Logging device
A SATADOM or local SATA/SCSI SSD is chosen as the location for the vSphere logging partition (/scratch partition). This partition may be but need not be on the boot disk and this applies to Autodeploy hosts which lack a boot disk.
This usage model has been supported since vSphere 7.0 for any SATA or SCSI connected SSD that is local. SATADOMs that meet the requirement set forth in Table 1 are also supported.
This usage model can be supported in a future release of vSphere for USB flash devices that meet the requirement set forth in Table 1.
SSD Endurance Criteria
The flash industry often uses Tera Bytes Written (TBW) as a benchmark for SSD endurance. TBW is the number of terabytes that can be written to the device over its useful life. Most devices have distinct TBW ratings for sequential and random IO workloads, with the latter being much lower due to Write Amplification Factor (WAF) (defined below). Other measures of endurance commonly used are DWPD (Drive Writes Per Day) and P/E (Program/Erase) cycles.
Conversion formulas are provided here:
Converting DWPD (Drive Writes Per Day) to TBW (Terabytes Written):
TBW = DWPD * Warranty (in Years) * 365 * Capacity (in GB) / 1,000 (GB per TB) Converting Flash P/E Cycles per Cell to TBW (Terabytes Written):
TBW = Capacity (in GB) * (P/E Cycles per Cell) / (1,000 (GB per TB) * WAF) WAF is a measure of the induced writes caused by inherent properties of flash technology. Due to the difference between the storage block size (512 bytes), the flash cell size (typically 4KiB or 8KiB bytes) and the minimum flash erase size of many cells one write can force a number of induced writes due to copies, garbage collection, etc. For sequential workloads typical WAFs fall in the range of single digits while for random workloads WAFs can approach or even exceed 100. Table 1 contains workload characterization for the various workloads excepting the Datastore and vSphere Flash Read Cache workloads which depend on the characteristics of the Virtual Machines workloads being run and thus cannot be characterized here. A WAF from the table can be used with the above P/E to TBW formula.

 

NEW QUESTION 13
The Virtual Infrastructure team wants to share a VM Template from vcsa0la to vcsa0lb via content libraries. Ensure that the content in the libraries is synchronized only when needed.
* Name of Published Content Library in vcsa0la: CL01
* Name of Subscribed Content Library in vcsa0lb: CL02
* For both content libraries, use the local datastore: SAN01
* VM Template to be shared: Core-Template
After the Core-Template has been synchronized from CL01 to CL02. deploy a virtual machine from VM-Template on vcsa0lb
* Name of virtual machine: CL-VM
* Host for virtual machine: sxi03b

  • A. Send us your suggestions.

Answer: A

 

NEW QUESTION 14
Your team is experiencing intermittent issues with esxi0la and you have been asked to configure the host to export its syslog data to a preconfigured syslog collector.
To complete this task, you must:
* Configure esxi0la.vciass.local to send syslog events to an external syslog collector on 172.20.10.10.
* Ensure that the ESXi host security policies allow the syslog traffic to pass.

  • A. Send us your suggestions.

Answer: A

 

NEW QUESTION 15
You are tasked to automate the installation and deployment of new host added into your company vSphere cluster using Auto Deploy. Ensure Auto Deploy and Image Builder is set to start automatically every time vCenter Server is restarted. Use the web client and VCSA0la to perform this step.
Confirm that the auto deploy plugin is available in the web interface. You may be required to logout and log back in after enabling the services.
The vCenter server is required to retrieve software from an online depot. You are to use the depot provided below and ensure that Auto Deploy is always running even, with restart of vCenter server.
Name FirstDepot
URL https / / hostupdate.vmware.com/software/VUB/PRODUCTION/main/vmw-depot-index.xml Note: ignore error that you received on cannot connect to depot. This is expected due to vCSA do not have internet connection.
Create a deploy Rule on VCSA0la based on information below. You do not need to apply to any host at this time.
Name: Rule1
Specify Rule to match Vendor: Dell
Check 'Do Not Include Image Profile"
Check 'Do Not Include Host Profile"
Select host location: Choose cluster PROD-A

Answer:

Explanation:
Before you can use vSphere ESXi Image Builder with the vSphere Web Client, you must verify that the service is enabled and running.
Procedure
Log in to your vCenter Server system by using the vSphere Web Client.
On the vSphere Web Client Home page, click Administration.
Under System Configuration click Services.
Select ImageBuilder Service, click the Actions menu, and select Edit Startup Type.
On Windows, the vSphere ESXi Image Builder service is disabled. In the Edit Startup Type window, select Manual or Automatic to enable Auto Deploy.
On the vCenter Server Appliance, the vSphere ESXi Image Builder service by default is set to Manual. If you want the service to start automatically upon OS startup, select Automatic.
If you select the manual startup type, you must start the service manually upon OS startup every time you want to use the service.
(Optional) Click the Start the service icon.
(Optional) If you want to use vSphere ESXi Image Builder with thevSphere Web Client, log out of the vSphere Web Client and log in again.
The Auto Deploy icon is visible on the Home page of the vSphere Web Client.

 

NEW QUESTION 16
A new internal network is required to isolate virtual machines for security analysis. The virtual machine (honeypot-01) should reside on a new virtual standard switch with the ability for all traffic on the switch to be monitored.
Add a new virtual switch to accommodate this requirement and configure (honeypot-01) to reside on this switch.
Use the following information to complete this task:
* ESXi host: esxi0la
* Standard Switch: Create a new Standard Switch
* Physical uplink: NO UPLINK
* Network Label: QUARANTINE
* VLAN: none specified

  • A. Send us your suggestions.

Answer: A

 

NEW QUESTION 17
......

Latest 3V0-22.21 Pass Guaranteed Exam Dumps Certification Sample Questions: https://pass4sure.test4cram.com/3V0-22.21_real-exam-dumps.html